- Physically place the AR99m receiver where it will be used, and extend the antennas vertically. The general rule of thumb is to maintain “line of sight” between the receiver and transmitter so that the person using or wearing the transmitter can see the receiver.
|
- With the AR99m powered off, connect the included power adapter.
- With your amplifier or mixer off and volume control all the way down, connect the AR99m receiver output jack to the mic or line level input of a mixer or amplifier using the balanced XLR output or unbalanced 1/4” or 1/8” line level outputs. Turn the VOLUME knob on the AR99m clockwise to turn its power on, but keep the level low.
|
|
- Press the SET button for more than 2 seconds (the display will start to flash quickly) on the front of the AR99m receiver to scan for an available channel. Once the optimal channel is selected the receiver will enter IR Set mode. The display will flash slowly in IR Set mode. If you want to set a transmitter to the receiver’s currently selected channel, press and hold the SET button for more than 10 seconds (until the display flashes slowly) to enter IR Set mode directly.
|
|
- Turn on the power to the AH9 transmitter by pressing and holding the Power button for 3 seconds; the indicator LED will light yellow when the button is pressed and turns green when released and the AH9 is powered on.
Note: The AH9 will only accept infrared transmission from the receiver for the first 10 seconds after the AH9 is powered on. If you need to change the operating channel, the AH9 must be first powered off, then powered on again to receive the new channel.
|
|
- Position the AH9 transmitter about 3–12” (8–30 cm) from the front of the AR99m with the transmitter’s IR window facing the IR transmitter on the front panel of the AR99m receiver.
|
|